Service Hints
B2 BRAKE FLUID LEVEL WARNING SW1-2 : Closed with float down
P5 PARKING BRAKE SW
1-GROUND : Closed with parking brake lever pulled up
C11 (A), C12 (B), C13 (C) COMBINATION METER
A. 1, (B) 5-GROUND : Always approx. 12 volts
A. 7, (B) 3-GROUND : Approx. 12 volts with ignition SW at ON or ST position
A. 12, (B) 15(C) 13-GROUND : Always continuity
W3 (A), (B) WATER TEMP. SENDER
A. 1, (B) 1-GROUND : Approx. 160 - 240 Ohms (50° C, 122° F)
: Approx. 17.1 - 21.2 Ohms (120° C, 248° F)