Heated Oxygen Sensor (Bank 1 Sensor 2)
INSPECTION1. INSPECT HEATER RESISTANCE OF HEATED OXYGEN SENSOR
a. Disconnect the oxygen sensor connector.
b. Using an ohmmeter, measure the resistance between terminals +B and HT.
Resistance: 11 - 16 ohm at 20 °C (68 °F)
If the resistance is not as specified, replace the sensor.
Torque: 44 N.m (450 kgf.cm, 32 ft.lbf)
c. Reconnect the oxygen sensor connector.
2. INSPECT OPERATION OF HEATED OXYGEN SENSOR.