Air-Fuel Ratio (A/F) Sensor
INSPECT HEATER RESISTANCE OF A/F SENSOR (No.2, No.3 Cylinder side)
a. Disconnect the A/F sensor connector.
b. Using an ohmmeter, measure the resistance between the terminals +B and HT.
Resistance:
1.8 - 3.4 ohms at 20 °C (68 °F)
5.0 - 7.5 ohms at 500 °C (932 °F)
If the resistance is not as specified, replace the sensor.
c. Reconnect the A/F sensor connector.