Combination Meter
COMBINATION METERB2 BRAKE FLUID LEVEL WARNING SW
1 - 2 : Closed with float down
P5 PARKING BRAKE SW
1 - GROUND : Closed with parking brake lever pulled up
C11 (A), C12 (B), C13 (C) COMBINATION METER
(A) 1, (B) 5 - GROUND : Always approx. 12 volts
(A) 7, (B) 3 - GROUND : Approx. 12 volts with ignition SW at ON or ST position
(A) 12, (B) 15, (C) 13 - GROUND : Always continuity
W3 (A), (B) WATER TEMPERATURE SENDER
(A) 1, (B) 1 - GROUND : Approx. 160 - 240 ohms (50°C, 122°F)
: Approx. 17.1 - 21.2 ohms (120°C, 248°F)
INTERIOR LIGHT
C11 (A), C12 (B) COMBINATION METER
(A) 7 - GROUND : Approx. 12 volts with ignition SW at ON or ST position
(B) 5 - GROUND : Always approx. 12 volts
(B) 7 - GROUND : Continuity with each door open
(B) 10 - GROUND : Continuity with front LH door open (Standard cab)
: Continuity with each LH door open (Access cab)