Service Hints

POWER WINDOW

D16, D17 DOOR COURTESY SW LH, RH
1 - GROUND : Continuity with door open

INTEGRATION RELAY
9 - GROUND : Approx. 12 volts with ignition SW at ON position
3 - GROUND : Always approx. 12 volts
14 - GROUND : Continuity with front LH door open (Standard cab)
14 - GROUND : Continuity with each LH door open (Access cab)
15 - GROUND : Continuity with front RH door open (Standard cab)
15 - GROUND : Continuity with each RH door open (Access cab)

P9 POWER WINDOW CONTROL SW RH
4 - GROUND : Approx. 12 volts with ignition SW on and stays at 12 volts for 41.5 - 44.5 seconds after the ignition SW is turned off, but if a door is open in the 45 seconds period, voltage will drop to 0 volts

P10 POWER WINDOW MASTER SW
1 - GROUND : Always continuity
9 - GROUND : Approx. 12 volts with ignition SW on and stays at 12 volts for 41.5 - 44.5 seconds after the ignition SW is turned off, but if a door is opened in this 41.5 - 44.5 seconds period, voltage will drop to 0 volts
3 - GROUND : Approx. 12 volts with ignition SW at ON position and master SW at UP position
4 - GROUND : Approx. 12 volts with ignition SW at ON position and master SW at DOWN or AUTO DOWN position

WINDOW LOCK SW
Open with window lock SW at LOCK position