Starter Relay: Testing and Inspection
STARTER RELAY ASSEMBLY
a. Inspect the relay continuity.
1. Using an ohmmeter, check that there is continuity between terminals 1 and 2.
If there is no continuity, replace the relay.
2. Check that there is no continuity between terminals 3 and 5.
If there is continuity, replace the relay.
b. Inspect the relay operation.
1. Apply battery positive voltage across terminals 1 and 2.
2. Using an ohmmeter, check that there is continuity between terminals 3 and 5.
If there is no continuity, replace the relay.