Component Tests and General Diagnostics
INSPECTION1. INSPECT LEFT SIDE MIRROR SWITCH CONTINUITY
If continuity is not as specified, replace the switch.
2. INSPECT RIGHT SIDE MIRROR SWITCH CONTINUITY
If continuity is not as specified, replace the switch.
3. INSPECT MIRROR MOTOR OPERATION
a. Connect the positive (+) lead from the battery to terminal 3 and the negative (-) lead to terminal 1, and check that the mirror turns to out side.
b. Reverse the polarity, and check that the mirror turns to in side.
c. Connect the positive (+) lead from the battery to terminal 3 and the negative (-) lead to terminal 5, and check that the mirror turns to the downward.
d. Reverse the polarity, and check that the mirror turns to the upward.
If operation is not as specified, replace the mirror assembly.