Component Tests and General Diagnostics
INSPECTION1. INSPECT TURN SIGNAL SWITCH CONTINUITY
If continuity is not as specified, replace the switch.
2. INSPECT TURN SIGNAL FLASHER OPERATION
Disconnect the connector from the turn signal flasher and inspect the connector on the wire harness side,as shown.
3. INSPECT HAZARD WARNING SWITCH CONTINUITY
a. Remove the center cluster finish panel.
b. Disconnect the connector from the center cluster integration.
c. Check that continuity exists between terminal 17 and terminal 1 with the switch ON.
d. Check that no continuity exists between terminal 17 and terminal 1 with the switch OFF.
If continuity is not as specified, replace the switch.