On-Vehicle Inspection
INSPECT CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLYa. Check the operation.
1. Turn the ignition switch to ON.
2. Turn the hand-held tester ON.
3. Start the engine and warm it up.
4. Select the following menu items: DIAGNOSIS / ENHANCED OBD II / ACTIVE TEST / VVT CTRL B1.
5. Operate the OCV using the hand-held tester, then check the engine speed.
If the operation is not as specified, check the camshaft timing oil control valve, wire harness and ECM.