Power Outlet Socket Assy
POWER OUTLET SOCKET ASSEMBLY
REPLACEMENT
1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
2. REMOVE POWER OUTLET SOCKET ASSEMBLY
a. Using a torx(R) socket wrench (T30), remove the 4 screws.
b. Disconnect the connector.
c. Remove the clamp and the power outlet socket assembly.
3. INSTALL POWER OUTLET SOCKET ASSEMBLY
a. Install the clamp.
b. Connect the connector.
c. Using a torx(R) socket wrench (T30), install the 4 screws and the power outlet socket assembly.
Torque: 5.0 N.m (51 kgf.cm, 44 in.lbf)
NOTE: Install the screws in the order shown the illustration.
4. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
Torque: 3.9 N.m (40 kgf.cm, 35 in.lbf)