Variable Valve Timing Actuator: Service and Repair
Camshaft Timing Oil Control Valve Assembly:
REMOVAL
1. REMOVE THROTTLE BODY COVER
2. REMOVE INTAKE AIR CONNECTOR
3. REMOVE CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY
a. Disconnect the 2 camshaft oil control valve connectors.
b. Remove the bolt, camshaft oil control valve and Oring.
Torque: 7.5 N.m (76 kgf.cm, 66 in.lbf)
c. Remove the O-ring from the each camshaft oil control valve.
HINT: At the time of installation, please refer to the following items. Use a new O-rings.
INSTALLATION
Installation is in the reverse order of removal.