Operation CHARM: Car repair manuals for everyone.

Plasmacluster Circuit








AIR CONDITIONING: AIR CONDITIONING SYSTEM: Plasmacluster Circuit

Plasmacluster Circuit

DESCRIPTION

The plasmacluster operates in conjunction with blower switch operation.

WIRING DIAGRAM





INSPECTION PROCEDURE

PROCEDURE

1. INSPECT AIR CONDITIONING AMPLIFIER





(a) Remove the A/C amplifier with the connectors still connected.
(b) Turn the power switch on (IG).
(c) Measure the voltage according to the value(s) in the table below.

Standard voltage:





NG -- CHECK HARNESS AND CONNECTOR (ION GENERATOR - BODY GROUND)
OK -- PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE
2. CHECK HARNESS AND CONNECTOR (ION GENERATOR - BODY GROUND)





(a) Disconnect the connector from the ion generator.
(b) Measure the resistance according to the value(s) in the table below.

Standard resistance:





NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR
OK -- Continue to next step.
3. CHECK HARNESS AND CONNECTOR (ION GENERATOR - BATTERY)





(a) Measure the voltage according to the value(s) in the table below.

Standard voltage:





NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR
OK -- Continue to next step.
4. CHECK HARNESS AND CONNECTOR (ION GENERATOR - A/C AMPLIFIER)





(a) Disconnect the connector from the A/C amplifier.





(b) Measure the resistance according to the value(s) in the table below.

Standard resistance:





NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR
OK -- REPLACE ION GENERATOR