ABS/TCS - Zero Point Calibration Information

T-SB-0020-08

March 25, 2008

Disconnect Battery & Perform Zero Point Calibration After Wheel Alignment Adjustment

Service Category
Brake

Section
Brake Control/Dynamic Control System

Market USA





Applicability

Introduction

The purpose of this TSB is to provide information on when and how to perform the zero point calibration on vehicles equipped with Vehicle Stability Control (VSC). Momentarily disconnecting the battery is a necessary step for performing the zero point calibration.





Warranty Information





Required Tools & Equipment

^ Additional TIS techstream units may be ordered by calling Approved Dealer Equipment (ADE).

^ The Toyota Diagnostic Tester and CAN Interface Module may also be used to perform the service procedures listed in this bulletin.

Preliminary Information

Perform this procedure if any of these repairs have been performed on the vehicle:

^ Wheel alignment has been adjusted.

^ Any chassis components have been removed/installed or replaced.

Repair Procedure

1. Disconnect the cable from the negative (-) battery terminal for MORE THAN two (2) seconds.

2. Reconnect the cable to the negative (-) battery terminal.

3. Perform the applicable zero point calibration of the yaw rate sensor and/or the steering angle sensor.

HINT
Refer to the applicable TSB or Repair Manual for the zero point calibration procedure.

4. Re-initialize all applicable systems available on the vehicle (power window sunroof power lift door etc.).