Plasmacluster Circuit
AIR CONDITIONING: AIR CONDITIONING SYSTEM: Plasmacluster Circuit
- Plasmacluster Circuit
DESCRIPTION
The plasmacluster operates in conjunction with blower switch operation.
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
1. INSPECT AIR CONDITIONING AMPLIFIER
(a) Remove the A/C amplifier with the connectors still connected.
(b) Turn the ignition switch on (IG).
(c) Measure the voltage according to the value(s) in the table below.
Standard voltage:
NG -- CHECK HARNESS AND CONNECTOR (ION GENERATOR - BODY GROUND)
OK -- PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE
2. CHECK HARNESS AND CONNECTOR (ION GENERATOR - BODY GROUND)
(a) Disconnect the connector from the ion generator.
(b) Measure the resistance according to the value(s) in the table below.
Standard resistance:
NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR
OK -- Continue to next step.
3. CHECK HARNESS AND CONNECTOR (ION GENERATOR - BATTERY)
(a) Measure the voltage according to the value(s) in the table below.
Standard voltage:
NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR
OK -- Continue to next step.
4. CHECK HARNESS AND CONNECTOR (ION GENERATOR - A/C AMPLIFIER)
(a) Disconnect the connector from the A/C amplifier.
(b) Measure the resistance according to the value(s) in the table below.
Standard resistance:
NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR
OK -- REPLACE ION GENERATOR