Room Temperature Sensor Circuit - Air Conditioning System (for Automatic Air Conditioning System)
HEATING / AIR CONDITIONING: AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System): B1411/11: Room Temperature Sensor Circuit
B1411/11 - Room Temperature Sensor Circuit
DESCRIPTION
This sensor detects the cabin temperature that is used as the basis for temperature control and sends a signal to the A/C amplifier.
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
1. READ VALUE USING TECHSTREAM
(a) Connect the Techstream to the DLC3.
(b) Turn the ignition switch to ON and turn the Techstream main switch on.
(c) Select the item below in the Data List, and read the display on the Techstream.
Data List / Air Conditioner
Data List / Air Conditioner:
OK:
The display is as specified in the "Normal Condition" column.
Result:
C -- REPLACE AIR CONDITIONING AMPLIFIER Removal
B -- PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE Air Conditioning System (For Automatic Air Conditioning System)
A -- Continue to next step.
2. INSPECT ROOM TEMPERATURE SENSOR
(a) Remove the room temperature sensor.
(b) Disconnect the connector from the room temperature sensor.
(c) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
NOTICE:
* Hold the sensor only by its connector. Touching the sensor may change the resistance value.
* When measuring, the sensor temperature must be the same as the ambient temperature.
HINT
As the temperature increases, the resistance decreases (see the graph).
NG -- REPLACE ROOM TEMPERATURE SENSOR Removal
OK -- Continue to next step.
3. CHECK HARNESS AND CONNECTOR (ROOM TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER)
(a) Disconnect the connector from the A/C amplifier.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR
OK -- REPLACE AIR CONDITIONING AMPLIFIER Removal