Door Lock - Smart Key System
DOOR LOCK: SMART KEY SYSTEM: DATA LIST / ACTIVE TEST
1. READ DATA LIST
HINT
Using Techstream to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
(a) Connect Techstream to the DLC3.
(b) Turn the engine switch on (IG).
(c) Turn the tester on. When Techstream cannot be turned on due to a malfunction or other problem, refer to PRECAUTIONS WHEN USING TECHSTREAM Door Lock - Smart Key System.
(d) Enter the following menus:
Body Electrical / Smart Key or Main Body / Data List.
(e) Read the Data List according to the display on the tester.
2. PERFORM ACTIVE TEST
HINT
Using Techstream to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
(a) Connect Techstream to the DLC3.
(b) Turn the engine switch on (IG).
(c) Turn the tester on.
(d) Enter the following menus:
Body Electrical / Smart Key / Active Test.
(e) Perform the Active Test according to the display on the tester.