A750E
A750E AUTOMATIC TRANSMISSION: AUTOMATIC TRANSMISSION SYSTEM: P2716: Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)
P2716 - Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)
DESCRIPTION
Refer to DTC P2714 P2714.
MONITOR DESCRIPTION
When an open or short in the shift solenoid valve (SLT) circuit is detected, the ECM interprets this as a fault. The ECM will turn on the MIL and store the DTC.
MONITOR STRATEGY
TYPICAL ENABLING CONDITIONS
All
Condition (A)
Condition (B)
TYPICAL MALFUNCTION THRESHOLDS
When either condition below is met: Condition (A) or (B)
Condition (A)
Condition (B)
COMPONENT OPERATING RANGE
WIRING DIAGRAM
INSPECTION PROCEDURE
NOTICE:
Perform the universal trip to clear permanent DTCs .
PROCEDURE
1. INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLT)
(a) Disconnect the D63 transmission wire connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard resistance:
NG -- INSPECT SHIFT SOLENOID VALVE SLT
OK -- Continue to next step.
2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
(a) Disconnect the D74 ECM connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard resistance:
NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR
OK -- REPLACE ECM Removal
3. INSPECT SHIFT SOLENOID VALVE SLT
(a) Remove shift solenoid valve SLT.
(b) Measure the resistance according to the value(s) in the table below.
Standard resistance:
(c) Connect the battery's positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating noise.
OK:
Valve moves and makes an operating noise.
NG -- REPLACE SHIFT SOLENOID VALVE SLT
OK -- REPAIR OR REPLACE TRANSMISSION WIRE