Operation CHARM: Car repair manuals for everyone.

Theft Deterrent System











THEFT DETERRENT: THEFT DETERRENT SYSTEM: SYSTEM DIAGRAM






THEFT DETERRENT: THEFT DETERRENT SYSTEM: SYSTEM DESCRIPTION

1. OUTLINE OF THEFT DETERRENT SYSTEM

(a) The theft deterrent system is designed to deter vehicle break-ins and theft. If an attempted break-in or theft is detected, the vehicle horns and security horn will sound and the hazard warning lights will flash.

(b) The system detects an attempted break-in or theft when any of the following occurs: 1) the vehicle is forcibly entered, 2) the engine hood is forcibly opened, 3) the doors are unlocked without the use of a key, or 4) the cable from the negative (-) battery terminal is disconnected and reconnected.

(c) If the system enters the alarm sounding state, any unlocked doors will automatically lock.

(d) The system has 2 modes: active arming mode (refer to "ACTIVE ARMING MODE") and passive arming mode (refer to "PASSIVE ARMING MODE"). Passive arming mode can be turned on and off using the Techstream.

(e) Each mode has 4 states: disarmed state, arming preparation state, armed state and alarm sounding state.

(1) Disarmed state:

* The alarm function is not operating.

* The theft deterrent system is not operating.

(2) Arming preparation state:

* The theft deterrent system is not operating.

(3) Armed state:

* The theft deterrent system is operating.

(4) Alarm sounding state:

* The alarm function is operating (60 +/-5 seconds).





HINT
If, during the alarm sounding state, one of the doors is unlocked without using the proper key, a forced door lock signal will be output (refer to "FORCED DOOR LOCK CONTROL").

2. FUNCTION OF MAIN COMPONENT





HINT
*: w/ Glass Breakage Sensor

3. SYSTEM FUNCTION

(a) Disarmed state:

* The alarm function is not operating.

* The theft deterrent system is not operating.

(b) Arming preparation state:

* The theft deterrent system is not operating.

(c) Arming state:

* The theft deterrent system is operating.

(d) Alarm sounding state:

* The alarm function is operating (60 +/-5 seconds).