Operation CHARM: Car repair manuals for everyone.

Blower Motor Circuit





HEATING / AIR CONDITIONING: AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System): Blower Motor Circuit
- Blower Motor Circuit

DESCRIPTION

The blower with fan motor sub-assembly is operated by signals from the air conditioning amplifier assembly. Blower motor speed signals are transmitted in accordance with changes in the duty ratio.

WIRING DIAGRAM





INSPECTION PROCEDURE

NOTICE:
Inspect the fuses for circuits related to this system before performing the following inspection procedure.

PROCEDURE

1. PERFORM ACTIVE TEST USING TECHSTREAM

(a) Connect the Techstream to the DLC3.

(b) Turn the ignition switch to ON.

(c) Turn the Techstream on.

(d) Enter the following menus: Body Electrical / Air Conditioner / Active Test.

(e) Check the operation by referring to the table below.

Air Conditioner





Result:





B -- CHECK HARNESS AND CONNECTOR (BLOWER WITH FAN MOTOR SUB-ASSEMBLY - BODY GROUND)

C -- INSPECT AIR CONDITIONING AMPLIFIER ASSEMBLY

A -- PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE Air Conditioning System (for Automatic Air Conditioning System)

2. CHECK HARNESS AND CONNECTOR (BLOWER WITH FAN MOTOR SUB-ASSEMBLY - BODY GROUND)

(a) Disconnect the I76 blower with fan motor sub-assembly connector.

(b) Measure the resistance according to the value(s) in the table below.

Standard Resistance:





NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR
OK -- Continue to next step.

3. CHECK HARNESS AND CONNECTOR (BLOWER WITH FAN MOTOR SUB-ASSEMBLY - BATTERY)

(a) Measure the voltage according to the value(s) in the table below.

Standard Voltage:





NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR
OK -- Continue to next step.

4. CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - BLOWER WITH FAN MOTOR SUB-ASSEMBLY)

(a) Disconnect the I77 air conditioning amplifier assembly connector.

(b) Measure the resistance according to the value(s) in the table below.

Standard Resistance:





NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR
OK -- Continue to next step.

5. INSPECT BLOWER WITH FAN MOTOR SUB-ASSEMBLY

(a) Reconnect the I76 blower with fan motor sub-assembly connector.

(b) Measure the voltage according to the value(s) in the table below.





Standard Voltage:





Text in Illustration





NG -- REPLACE BLOWER WITH FAN MOTOR SUB-ASSEMBLY Removal
OK -- Continue to next step.

6. INSPECT AIR CONDITIONING AMPLIFIER ASSEMBLY

(a) Remove the air conditioning amplifier assembly Removal.





(b) Reconnect the air conditioning amplifier assembly connector.

(c) Turn the ignition switch to ON.

(d) Turn the blower switch on (LO).

(e) Measure the waveform between terminal I77-22 (BLW) of the air conditioning amplifier assembly and body ground.

OK:

Waveform is similar to that shown in the illustration.

HINT
The waveform varies with the blower speed.





Text in Illustration





NG -- REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY Removal

OK -- REPLACE BLOWER WITH FAN MOTOR SUB-ASSEMBLY Removal