Installation
2AR-FE INTAKE / EXHAUST: VACUUM SWITCHING VALVE (for ACIS): INSTALLATION
1. INSTALL VACUUM SWITCHING VALVE ASSEMBLY (for ACIS)
(a) Install the vacuum hose clamp with the bolt.
Torque : 5.4 Nm (55 kgf-cm, 48 in-lbf)
(b) Install the vacuum switching valve assembly with the bolt.
Torque : 9.0 Nm (92 kgf-cm, 80 in-lbf)
(c) Connect the 2 vacuum hoses and connector.
(d) Connect the union to connector tube hose and wire harness clamp.