A/T - Shift Points, Stall Speed, Pressure Specifications
84VW03Applies To CONVERTIBLE, JETTA
RABBIT, SCIROCCO
Group
37
Subject Automatic
transmission 010 - code letters TF, TH
Part Identifier N/A
Key Points
Shift points, stall speed and main pressure specifications
A-084
Number
84-01
January 16, 1984
Listed below are shift points, stall speed and main pressure specifications for 010 automatic transmissions with code letters TF, TH
Note When checking shift points, note that speedometer readings may vary within permissible manufacturing tolerances..
STALL SPEED
Transmission Torque converter Stall speed
code letters code letter (rpm)
TF M 2300-2600
TH X 2500-2800
CAUTION
Do not continue stall speed test longer than time required to read tachometer. Maximum stall speed test time 5 seconds. If necessary to repeat test, wait at least 20 seconds.
Note
Normal stall speed will drop 125 rpm per 3200 ft altitude. Stall speed will also drop slightly at high ambient air temperature.
- if stall speed is not as specified, following items may be wrong: