Hall Sender, Checking
Hall sender, checking
Requirement
Electrical checks (wiring and component checks) OK
Voltage supply, checking
- Disconnect Hall sender (distributor) and connect multimeter US 1119 to outer terminals of Hall sender connector
- Switch ignition ON
Specified value: minimum 10 volts
If NO
- Replace control unit
- Switch ignition OFF
Function, checking
- Slip back rubber boot from Hall sender connector
- Ground coil wire (use adaptor if necessary)
- Connect voltage tester US 1115 to center and outer contacts of Hall sender connector (if necessary, use jumper wire)
- Operate starter and check signal from Hall sender
If LED flickers, Hall sender is OK
If NO
- Replace Hall sender