Operation CHARM: Car repair manuals for everyone.

Vacuum and Vapor Hose Diagrams





NOTE: Insertion depth of vacuum hose in vacuum reservoir: 30 mm. Overlap of vacuum hose on plastic line: onto stop (approx. 15 mm)

1- Fresh air/recirculating air flap vacuum unit
2- Reduction hose
3- Hose
3.5 x 2 x 90 mm
4
- Plastic line
4 x 1 x 950 mm
5
- Plastic line
4 x 1 x 1030 mm
6
- Foam line
7- Plastic line
4 x 1 x 490 mm
8
- Vacuum reservoir
9- Cable tie
10- Non-return valve
Direction of suction indicated by arrow
11- Hose
3.5 x 2 x 40 mm
12
- T-connection
13- Two way valve for fresh/ recirculating air flap -N63-
14- Hose
3.5 x 2 x 350 mm
15
- Hose
3.5 x 2 x 245 mm
16
- Hose
3.5 x 2 x 116 mm
17
- Hose
3.5 x 2 x 116 mm
18
- Non-return valve