Reading Measuring Value Blocks
Read Measuring Value Block, Initiating
Special tools, workshop equipment, testers, measuring instruments and auxiliary items required
- VAG 1551/1552 Scan Tool using VAG 1551/3 adaptor cable.
Initiation sequence
- Connect VAG 1551/1552 Scan Tool. [1][2][3][4]Reading and Clearing Diagnostic Trouble Codes
- Start engine and let idle.
- Press 0 and 1 buttons to select "Engine electronics" address word 01.
Indicated on display (example only)
06A906018AB Motronic M5.9.2 HS V06 ->
Coding 00000 WSC 00000
- Press -> button.
Indicated on display
Rapid data transfer HELP
Select function XX
- Press 0 and 8 buttons to select "Read measuring value block" function 08.
- Press -Q- button to confirm input.
Indicated on display
Read measuring value block
Input Display group number XXX
Requirements (Once Scan Tool is functional)
- All electrical consumers must be switched OFF
- A/C switched OFF (if installed)
- Automatic Transmission Range selector lever in "P" or "N" position
- No malfunctions stored in DTC memory
- Engine Coolant Temperature 85 °C minimum See Display group 04, field 3
- Select required Display group number.
NOTE: Display group number 0 is an example, to illustrate the sequence.
- Press 0, 0 and 0 buttons to select "Display group 0"
- Press -Q- button to confirm input.
Indicated on display (1 to 10 = Display fields)
Read measuring value block 0 ->
1 2 3 4 5 6 7 8 9 10
NOTE: To change to another display group proceed as follows:
If specifications in all display fields obtained:
- Press -> button.
If one of the specifications not obtained. Evaluating Measuring Value Blocks
Indicated on display
Rapid data transfer HELP
Select function XX
- Press -0- and -6- buttons to select "End output" function 06.
- Press -Q- button to confirm input.