Central Locking System, Adaptation

Unlocking options

- Selective unlocking
- All doors unlock simultaneously

- Connect VAG 1551/1552 Scan Tool to Data Link Connector (DLC). Refer to "Connecting VAG 1551 Scan Tool\Scan Tool Connecting and Initial Checks\Scan Tool Testing" Scan Tool Connecting and Initial Checks

Vehicles with power windows
- Enter address word 46, Comfort System and select function 07, Code Control Module.







Locking options
- Automatic lock/unlock (all doors are locked automatically at 15 km/h / 10 mph and unlocked when key is removed from ignition switch).
- Alarm system confirmation signals on or off

- Connect VAG 1551/1552 Scan Tool to Data Link Connector (DLC). Refer to "Connecting VAG 1551 Scan Tool\Scan Tool Connecting and Initial Checks\Scan Tool Testing" Scan Tool Connecting and Initial Checks

Vehicles with power windows
- Enter address word 46 to select "Comfort System" and press -Q- button to confirm input. Select function 10 "Adaptation" and press -Q- button to confirm input.
- Press the -> button as many times as necessary to advance to "insert adaptation channel".
- Review available channel function descriptions in table below.
- Using the VAG 1551/1552 keypad, enter the corresponding adaptation value either directly or step-by-step. For a step-by-step adaptation example.







Step-by-step adaptation example (activating "Auto lock/unlock")

Indicated on display


Adaptation
Insert channel number XX



- Press buttons -0- and -3- to insert channel 3 (Auto lock/unlock function).

Indicated on display


Adaptation Q
Insert channel number 03



- Press -Q- button to confirm input.

Indicated on display (0 = Auto lock/unlock off)


Channel 3 Adaptation 0 ->
Auto lock/unlock off <- 13 ->



- Press -> button

Indicated on display


Channel 3 Adaptation 0 ->
Enter adaptation value XXXXX



- Press -> button.
- Press -0- button four times and -1- button once.

Indicated on display


Channel 3 Adaptation 0 Q
Enter adaptation value 00001



- Press -Q- button to confirm input.

Indicated on display (1 = Auto lock/unlock on)


Channel 3 Adaptation 1 Q
Auto lock/unlock on <- 13 ->



- Press -Q- button to confirm input.

Indicated on display


Channel 3 Adaptation 1 Q
Store changed value?



- Press -Q- button to confirm input.

Indicated on display


Channel 3 Adaptation 1 ->
Changed value is stored



- Press -> button

Indicated on display


Rapid data transfer HELP
Select function XX



- Press buttons -0- and -6- to select function 06, "End Output".

Indicated on display


Rapid data transfer HELP
Insert address word XX



- Disconnect VAG 1551/1552 from Data Link Connector (DLC).