Reading
Read Measuring Value Block
WARNING!
- Only visual check of wiring!
- Do not carry out electrical continuity tests or measurements to ignition circuits!
- Only check wiring with ignition switched off!
Indicated on display:
Rapid data transfer HELP
Select function XX
- Press keys -0- and -8- (08 initiates the "Read Measuring Value Block" function).
Indicated on display:
Rapid data transfer Q
08 Read Measuring Value Block
- Confirm entry with the -Q- button.
Indicated on display:
Read Measuring Value Block HELP
Input display group number XXX
- Select relevant display group number and confirm entry with -Q- button.
Indicated on display: (1 to 4 See Display zones)
Read Measuring Value Block 1 ->
1 2 3 4
The explanation of the individual display zones on the display is found in the evaluation of display group numbers.
NOTE: Some of the indicated display groups are only meaningful for respective vehicle equipment (e.g side airbag).
If the displayed values in all display zones are "correct";
- Press -> button.
Indicated on display:
Rapid data transfer HELP
Select function XX
NOTE: Check DTC memory after completing the function "Read Measuring Value Block".