Matching Ignition Keys to Radio Wave Remote Control
Ignition Keys, Matching To Radio Wave Remote Control
NOTE:
- If new or additional ignition keys are required they must be matched to the immobilizer and convenience system control electronics.
- The matching procedure must always be carried out for all the ignition keys, including the existing ones.
- The number of keys already matched will be displayed when the adaptation (matching) function is selected.
- With the introduction of this generation of convenience system it is possible to program additional functions. The functions and the programming are described. Radio Wave Remote Control Function Variations (Convenience)
- The matching can be interrupted with the "C" key of the VAG 1551.
WARNING!
The VAG 1551 dealership number (workshop code) will be stored in immobilizer control unit when matching ignition keys.
Prerequisites
- All ignition keys available. If no old ignition key is available see "Lost key procedure",
- Key fob with covered secret number is available, if not see "Establishing secret number",
- Insert correct profile ignition key in the ignition lock.
- Connecting scan tool, initiating On Board Diagnostic (OBD).
Refer to "Scan Tool Testing/Scan Tool Connecting and Initial Checks", under "Restraint Systems", Testing and Inspection
Refer to "Scan Tool Testing, Initiating on Board Diagnostic (OBD)".Scan Tool Testing
The adaptation shown here is only an example.
Indicated on display:
Rapid data transfer HELP
Select function XX
- Press keys 1 and 0 (10 selects function "Adaptation").
Indicated on display:
Rapid data transfer Q
10 - Adaptation
- Confirm entry with the Q button.
Indicated on display:
Adaptation
Enter channel number XX
- Press keys 0 and 0 (all keys are erased with channel number 00).
- Confirm entry with the Q button.
NOTE: It is not possible to match a new or additional key(s) without erasing existing learnt/matched key(s).
Indicated on display:
Adaptation Q
Erase learned values
- Confirm entry with the Q button.
Indicated on display:
Adaptation
Learned values are erased
- Press -> button.
Indicated on display:
Rapid data transfer HELP
Select function XX
- Press keys 1 and 0 (10 selects function "Adaptation").
Indicated on display:
Rapid data transfer Q
10 - Adaptation
- Confirm entry with the Q button.
Indicated on display:
Adaptation
Enter channel number XX
- Press keys 0 and 1 (all keys are "learnt" with channel number 01).
Indicated on display:
Adaptation Q
Enter channel number 01
- Confirm entry with the Q button.
Indicated on display:
Channel 1 ....... Adaptation 1 ->
Key 1 <-1 3->
The top line displays number of keys to be "learned" (standard = 1). Select number of keys with keys 1 and 3.
- Press -> button.
Indicated on display:
Channel 1 ...... Adaptation 1 ->
Enter matching value XXXXX
- Press the 0 key four times and then enter the number of all ignition keys to be matched, including the existing key, (e.g. 00003); max. possible Qty. 4.
- Press -> button.
Indicated on display: Number of radio wave key to be "learned".
Channel 1 Adaptation 3 Q
Key 3 <-1 3->
- Confirm entry with the Q button.
Indicated on display:
Channel 1 Adaptation 3 Q
Store amended value?
- Confirm entry with the Q button.
Indicated on display:
Channel 1 Adaptation 1 ->
Amended value is stored
- Press -> button.
Indicated on display:
Rapid data transfer HELP
Select function XX
- A button must be pressed once, for at least 1 second, on each of the radio wave keys to be "learned" (in example above, 3 keys).
- Switch off ignition and remove ignition key.
- Perform functional check (e.g. 3) of radio wave keys.
NOTE:
- All 3 keys (see example) can be "learned" in one matching sequence.
- 15 seconds must not be exceeded when matching all ignition keys (pressing a button).
- A successful adaptation can be determined via Read Measuring Value Block, function 08, display group number 013. When operation the radio wave unit both of first measurement values must have the status OK. Simultaneously the last measurement value will show the positional number of the key (i.e. first, second, third, fourth key).
Refer to "Scan Tool Testing/Measuring Value Blocks/Evaluating Measured Value Blocks". Measuring Value Blocks (Function 08)
- If the remote control key is operated several times the third display -no measured value-changes to "OK".
The matching of ignition keys is automatically terminated when:
- number of keys to be matched is reached.
- a button of one of the keys to be "learned" is pressed frequently.
- Permissible matching period of 15 seconds is exceeded (DTC is stored).
- Select function 02 "Check DTC memory". If there is no DTC stored, the matching of the keys has been successfully completed.
- Press keys -0- and -6- to end the output.
Indicated on display:
Rapid data transfer Q
06 End output
- Confirm entry with the Q button.
Indicated on display:
Rapid data transfer HELP
Enter address word XX
- Switch off ignition.
- Disconnect connector to scan tool VAG 1551.