Operation CHARM: Car repair manuals for everyone.

Oxygen Sensor Regulation Before Catalytic Converter, Checking






Diagnostic Procedures

Oxygen Sensor Regulation Before Catalytic Converter, Checking

Use only gold-plated terminals when servicing terminals in the electrical harness connector of the Heated Oxygen Sensor (HO2S) (G39 ).

Special tools, testers and auxiliary items required

Multimeter.

Wiring diagram.

Test requirements

The Heated Oxygen Sensor (HO2S) (G39) fuse OK.

The Oxygen Sensor (O2S) Heater (G39) before catalytic converter OK.

Battery voltage at least 12.5 volts.

All electrical consumers such as, lights and rear window defroster, switched off.

A/C switched off.

Ground connections between engine/transmission/chassis OK.

Exhaust system between catalytic converter and cylinder head properly sealed.

Coolant Temperature at least 80 °C.

Test procedure

- Perform a preliminary check to verify the customers complaint. Refer to => [ Preliminary Check ] Preliminary Check

If an O2 sensor heater code is also set, perform the test for the O2 heater first.

Start diagnosis

- Connect scan tool.

- Start the engine and let it run at idle.

- Select "Diagnostic mode 6: Check test results of components that are not continuously monitored".

- Select "Test-ID 01: Oxygen sensor monitoring before catalytic converter".

- Select "Test-ID 131: Dynamic test".

- Check the specified values at idle.





If the specified value was obtained:

- Switch the ignition OFF. Fault is not active at this time. Check for poor connections, loose terminals and harness check.

If the specified value was Not obtained:

Checking primary voltage

- Disconnect the Heated Oxygen Sensor (HO2S) (G39 ) electrical harness connector - 1 -.





- Using a multimeter, check the Heated Oxygen Sensor (HO2S) (G39) electrical harness connector - 1 - terminals 1 to 2 for voltage.





Specified value: 0.400 to 0.500 Volts

If the specified value was obtained:

- Replace the Heated Oxygen Sensor (HO2S) (G39) Refer to the repair information.

If the specified value was Not obtained:

Checking wiring

If the manufacturers test box is being used, perform the following step.

- Install the test box.

If the manufacturers test box is not being used, perform the following step.

- Remove the Motronic Engine Control Module (ECM) ( J623). Refer to the repair information.

- Using a multimeter, check the Heated Oxygen Sensor (HO2S) (G39) electrical harness connector terminals to the Motronic Engine Control Module (ECM) (J623) electrical harness connector T94 terminals for an open circuit.









Specified value: 1.5 ohms Max.

If the specified value was Not obtained:

- Check the wiring for an open, high resistance or short to ground.

- Check the electrical harness connector for damage, corrosion, loose or broken terminals.

- If necessary, repair the faulty wiring connection.

If no malfunction is found in the wiring:

- Replace the Motronic Engine Control Module (ECM) (J623). Refer to the repair information.

Final procedures

After the repair work, the following work steps must be performed in the following sequence:

1. Check the DTC memory. Refer to => [ Diagnostic Mode 03 - Read DTC Memory ] Scan Tool Testing and Procedures.

2. If necessary, erase the DTC memory. Refer to => [ Diagnostic Mode 04 - Erase DTC Memory ] Scan Tool Testing and Procedures.

3. If the DTC memory was erased, generate readiness code. Refer to => [ Readiness Code ] Monitors, Trips, Drive Cycles and Readiness Codes.