Operation CHARM: Car repair manuals for everyone.

Battery in Engine Compartment, Disconnecting and Connecting






Battery in Engine Compartment, Disconnecting and Connecting

CAUTION!
Risk of injury. Observe warning notes and safety precautions.

Disconnecting

By disconnecting the negative battery connection (opening the circuit), it is possible to safely work on the electrical system.

Disconnection of the battery positive terminal is only required for removal of the battery.

- Turn off the ignition and all electrical consumers.

- Open locking mechanism - arrow - and remove battery box cover.





- First, disconnect battery terminal clamp of Ground (GND) wire - 1 - from battery Ground (GND) terminal.





- Then, remove battery terminal clamp of positive wire - 2 - from battery positive terminal.

Connecting

CAUTION!
Observe notes for threaded connections of battery terminals.

Special tools, testers and auxiliary items required

Torque Wrench (V.A.G 1331)

After connecting the battery and switching on the ignition, the ASR/ESP Control Lamp (K155) lights up continuously. Control lamp goes out automatically when vehicle is driven a distance straight ahead at 15 to 20 km/h. This re-activates Steering Angle Sensor (G85).

CAUTION!
When disconnecting and connecting battery, the procedure must be followed as described in the repair information. Refer to => [ Battery, Disconnecting and Connecting ] Battery, Disconnecting and Connecting.

Central battery venting hose must not be kinked, closed and/or damaged. Battery acids pose health risks and are explosive. Carefully route the hose and ensure the battery can vent freely and not into inside of vehicle.

- Connect the positive wire battery terminal clamp - 2 - to the battery positive terminal and tighten the mounting bolt to the specification => [ Specifications ] Specifications.

- Connect the ground wire battery terminal clamp - 1 - to the battery negative terminal and tighten the mounting bolt to the specification => [ Specifications ] Specifications.





- Perform the work procedures in the table.

Work steps required after reconnecting battery





If necessary, the table can be printed out.