Procedures






B+ Cable Mount on Generator


If the B+ wire is not tightened to the specification, the following may occur:

Battery will not be completely charged.

The complete electrical/electronics systems may fail (disabled vehicle).

Fire hazard due to arcing.

Damage to electronic components and control modules caused by excessive voltage.


Follow the procedure in the Repair Information when disconnecting and connecting the battery. Refer to => [ Battery, Disconnecting and Connecting ] Battery, Disconnecting and Connecting.

Check the generator.

- Torque specification of B+ wire nut - arrow - is 15 Nm.