Signal Too High. Permanent Fault
Checking Signal Cable
- Connect the test box and check ground terminals.
- Connect an ohmmeter between test box # 26 (# B26) and ground.
- The ohmmeter should read 0 - 3 k ohms.
If reading is OK:
^ Check cable between engine control module (ECM) # B26 and transmission control module (TCM) # B15 for a short-circuit to supply voltage.
If reading is incorrect:
^ Check cable between engine control module # B26 and transmission control module # B15 for a short-circuit to supply voltage.
Fault-tracing Information
Fault-tracing for this diagnostic test is not followed by a verification.
- Do you want to repeat the fault-tracing for this diagnostic test?
Yes:
^ Return to Checking Signal Cable section above.
No:
^ Fault corrected