Operation CHARM: Car repair manuals for everyone.

CCM-0006









Condition
If control unit registers that signal from evaporator temperature sensor is less than 2% of excitation voltage (approximately 5 V), diagnostic trouble code CCM-0006 is displayed.

Condition
- Control unit assumes a substitute value equivalent to approximately 0°C (32°F).

Possible source
- Signal wire is short circuited to ground
- Defective evaporator temperature sensor.

Condition
- No cool air from A/C-system
- A/C compressor does not work or works intermittently
- Intermittent function of A/C-system.