Refrigerant, Draining






Refrigerant, draining

Draining refrigerant

Information





Note! The ambient temperature must be above 20°C when draining the system

When draining refrigerant, the recycling unit can be attached to the service valve for both the high pressure side (HP) and the low pressure side (LP) at the same time. This is the quickest method.
- The engine must be switched off
- Check the amount of oil (if any) that has run out when draining the refrigerant.

Note! The recycling unit must be equipped with an oil separator. The oil separator must be of a type that allows the amount of oil in the refrigerant to be measured.

Note! Always disconnect the battery lead when working on the climate control system. Disconnect the battery lead. See Battery, replacing Battery, Replacing.

Other information:
- For vacuum pumping, see Vacuum pumping Vacuum Pumping
- For visual and physical checks, see Visual and physical check Visual and Physical Check
- To fill with refrigerant, see Refrigerant, filling Refrigerant, Filling
- To fill with fluorescent tracing agent, see Filling with fluorescent tracing agent with the refrigerant Filling With Fluorescent Tracing Agent With the Refrigerant
- To leak trace using an electronic leak tracer, see Leak tracing, electronic leak tracer Leak Tracing, Electronic Leak Tracer
- To leak trace using fluorescent tracing agent and an UV flashlight, see Leak tracing, fluorescent tracing agent / UV lamp Leak Tracing, Fluorescent Tracing Agent / UV Lamp