Signal Too Low. Permanent Fault
Signal too low. Permanent fault
Checking back-up (reversing) lamp switch
- Ignition off.
Hint: Check the back-up (reversing) light switch resistance between connector 54/1 terminal #24 and ground with gears 1 to 5 engaged. Resistance should be high.
The back-up gear switch should be open in all gear positions except back-up gear.
Remedy as necessary.
Other information:
- To access the back-up (reversing) lamp switch, see Back-up lamp switch, replacing Service and Repair.
Was a fault detected?
Yes - Verification
No - Checking the cable
-------------------------------------------------
Checking the cable
Check the cable between the central electronic module (CEM) terminal #1A and the back-up (reversing) lamp switch terminal #2 (3/10). Check for a short-circuit to ground.
Remedy as necessary.
Other information:
- For information about the central electronic module (CEM), see Central electronic module (CEM), replacing Central Electronic Module (CEM), Replacing
- To access the back-up (reversing) lamp switch, see Back-up lamp switch, replacing Service and Repair
- Checking wiring and terminals Checking Wiring And Terminals.
Was a fault detected?
Yes - Verification
No - Replacing the component
-------------------------------------------------
Replacing the component
Try replacing the back-up (reversing) lamp switch.
Other information:
- To access the back-up (reversing) lamp switch, see Back-up lamp switch, replacing Service and Repair.
Continue - Verification
-------------------------------------------------
Verification
Verification
Verification
Hint: After the repair it is necessary to check that the fault has been rectified.
- Ignition off.
- Connect connectors, install components etc.
- Ignition on.
Reversing light should not come on when gears 1 to 5 are selected.
Does it work?
Yes - VERIFIED
No - VERIFICATION FAILED
------------------------
VERIFIED - Fault Found
VERIFICATION FAILED - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.
Do you want to exit fault-tracing?
Yes - FAULT-TRACING FAILED
No - Attempt New Test
------------------------
FAULT-TRACING FAILED - No Fault Found
Attempt New Test - Checking back-up (reversing) lamp switch
-------------------------------------------------