Signal Too Low. Intermittent Fault.
Signal too low. Intermittent fault.
Checking the wire
Check the wire between central electronic module (CEM) 17D and warning flasher 1 (3/6) for an intermittent short circuit to ground as described in Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults and for a loose contact as described in Checking wiring and terminals. Intermittent faults Checking Wiring and Terminals. Intermittent Faults.
Additional information:
- For information on the central electronic module (CEM) connector, see Central electronic module (CEM), replacing Central Electronic Module (CEM), Replacing
- To connect the test box, see Connecting the breakout box Connecting the Breakout Box, Central Electronic Module (CEM)
- For information on signals, see Signal specification Pinout Values and Diagnostic Parameters.
Continue - DONE
-------------------------------------------------