Configuration Fault
Configuration fault
Replacing software
Note! If possible, read off the programmed data before replacing software.
- Ignition off.
The upper electronic module (UEM) has registered a fault in the configuration file.
The fault may be due to a program fault. The software must be replaced.
Continue - Reading off programmed values
-------------------------------------------------
Reading off programmed values
Note! Read off the programmed values from the upper electronic module (UEM) before re-programming.
- Ignition on
- Click on the symbol for VCT2000 to read off the programmed values.
The obtained values are programmed customer parameters in the upper electronic module (UEM). These values should be noted for later use.
Other information
- For information about programming the customer parameters, see Diagnostic functions Diagnostic Functions.
Continue - Downloading software
-------------------------------------------------
Downloading software
Download new software. See Upper electronic module (UEM) rear view / door mirror, replacing Service and Repair.
Do not replace the control module.
Hint: If diagnostic trouble code (DTC) UEM-E001 is stored, communication with the control module cannot be established. This can be remedied in two ways.
1. Press the remote control button for local lighting
2. Remove fuse 11C/28 from the fusebox in the passenger compartment. Reinstall the fuse again.
Continue - Checking interior lighting
-------------------------------------------------
Checking interior lighting
Checking the interior lighting (2)
Checking the interior lighting
Two times can be programmed for the interior lighting:
1. Short
- The period from when the door is unlocked, or the engine stops, to when the interior lighting goes out can be changed if it is too long or too short.
2. Long
- The period from when the door is opened, or a lamp is lit with a switch, to when the lamp goes out can be changed if it is too long or too short.
To program a long interior lighting period you must step ("click") through the short interior lighting period programming.
Continue - Programming a short interior lighting period
------------------------
Programming a short interior lighting period
The general lighting and rear reading lamps light and remain lit for 30 seconds when:
- The door has been unlocked from outside with a key or the remote control.
- The engine has been stopped and the ignition key turned to 0.
The default period is 30 seconds. This can be changed to between 5 and 255 seconds.
Read off the programmed values.
To change the time, mark the desired value in the scrolling list and start programming.
Do you want to program any more parameters?
Yes - Programming a long interior lighting period
No - Fault Found
------------------------
Programming a long interior lighting period
The general lighting and rear reading lamps light and remain lit for 10 minutes when:
- A door is opened after being unlocked.
- The lamp is lit with a switch.
The default period is 10 minutes. This can be changed to between 0 and 255 minutes at 10 minute intervals.
Read off the programmed values.
To change the time, mark the desired value in the scrolling list and start programming.
Continue - Fault Found
------------------------
FAULT FOUND - Checking anti-dazzle function in rear view mirror
-------------------------------------------------
Checking anti-dazzle function in rear view mirror
Checking the anti-dazzle function in the rear view mirror
Checking the anti-dazzle function
Note! If the upper electronic module (UEM) has been replaced software, specially developed for downloading after replacing the control module, must be downloaded to the control module before the anti-dazzle function is changed. See Upper electronic module (UEM) rear view / door mirror, replacing Service and Repair.
The rear view mirror anti-dazzle function can be adjusted:
- If the rear view mirror anti-dazzle function is too powerful or too weak, it can be adjusted.
Specific software for setting the anti-dazzle function must be installed in the car to do this.
Order the software. See9499432.
Install the software. See9499432.
Continue - DONE
------------------------
DONE - Fault Found
-------------------------------------------------