Signal Specification, Transmission Control Module (TCM)
Signal specification
All values listed below are between the terminal in column 1 and terminal #A9 (#39 on the breakout box), unless otherwise indicated in brackets.
Note! Connect the breakout box and check the ground terminals before taking readings.
- Connector A (16-pin) corresponds to terminals #31 - #46 on the breakout box
- Connector B (4-pin) corresponds to terminals #51 - #54 on the breakout box
- Connector C (22-pin on transmission side) corresponds to terminals #1 - #22 on the breakout box.