Differential Lock






Component specification

Electric feed pump

General





Type
The electrical feed pump consists of a PWM controlled electrical motor and a gear pump.

characteristic
The resistance between terminal #1 and #2 should be approximately 3 - 5 ohms at +20 °C.

Other information
None.

Terminal










Check

Check 1
Measure the resistance between feed pump's terminal pin #1 and #2. The value should be approximately 3 - 5 ohms at +20 °C.

Check 2
Measure the resistance between the feed pump casing and terminal pin #1. The value should be much greater or infinite.

Check 3
Measure the resistance between the feed pump casing and terminal pin #2. The value should be much greater or infinite.