Signal Too Low
Signal too low
Checking the wiring and terminals
If the fault is intermittent, it has been registered previously but is no longer present. The fault is evaluated depending on how it occurs.
Check the cable between the central electronic module (CEM) and lighting in the cup holder/ashtray. Check for a short-circuit to ground.
Take readings between:
- Central electronic module (CEM) #D12 (#12) and the lighting in the cup holder/ashtray.
Check the connection at the LED and ensure that the cables are not short-circuited to each other.
Remedy as necessary.
Other information
- Connecting the breakout box Connecting The Breakout Box, Central Electronic Module (CEM)
- Signal specification Signal Description, Central Electronic Module (CEM)
- Location of components Locations
- Checking wiring and terminals Checking Wiring And Terminals
Continue - Verification
-------------------------------------------------
Verification
Hint: After carrying out the repair, check that the fault has been remedied.
- Ignition off.
- Reinstall the connectors, components etc.
- Ignition on.
Check that the LED lights.
Does the LED work as it should?
Yes - FAULT FOUND
No - Information
-------------------------------------------------
Information
Information
Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.
Do you want to exit fault-tracing?
Yes - Exit fault-tracing
No - Attempt New Test
------------------------
Attempt New Test - Checking the wiring and terminals
-------------------------------------------------