Operation CHARM: Car repair manuals for everyone.

Battery, Disconnecting and Connecting






Battery, Disconnecting and Connecting

Procedure

- Switch off ignition and remove ignition key.

Sedan:

- Lift and secure luggage compartment floor mat.

Avant:

- Remove luggage compartment storage area floor - 1 - and cover for spare wheel - 2 -.





All:

- Release battery strap - 1 - if present.





If the battery strap does not have a quick-release, then remove the screw on the strap.

- Release retaining clips - arrows - using a screwdriver - 2 - and remove ground (GND) terminal cap - 1 -.





Illustration shows molded insert removed.

- Loosen nut several turns and remove ground wire terminal clamp - arrow - from battery terminal.





Vehicles with Battery Monitoring Control Module (J367):

- Release the strap - arrow B - and open the cover over the battery negative terminal - arrow A - - 1 -.





- Disconnect the electrical connector - 1 - on the battery monitoring control module - 1 -.





All Vehicles

- To connect, connect terminal clamp of Ground (GND) wire by hand to battery negative terminal negative and tighten nut.

Vehicles with Battery Monitoring Control Module (J367):

- Connect the connector - 1 - on the battery monitoring control module - 2 -.





All Vehicles

When connecting the battery, perform the following steps:

Activate the power window regulator one-touch up/down function.

Synchronize the spare and additional keys to ensure remote control operation. To do so, insert key into ignition lock, switch the ignition on and off again and remove key.

Check the DTC memories of all the control units and erase under voltage the fault if necessary.

After connecting the power supply, the ABS warning lamp may only go out after the vehicle has been driven a few yards.

Tightening Specifications