Operation CHARM: Car repair manuals for everyone.

Air Guide In Evaporator Housing






Air Guide In Evaporator Housing

(In Heater Air Guide Channel)






1 Complete Evaporator Housing

Air guide channel on vehicles without A/C (with heating only).

2 Back Pressure/Fresh Air Door

Shown in "open" position.

Air conditioners (heaters) whose back pressure/fresh air door is operated by the Air Flow door Motor (V71) and whose recirculation door is operated by the Recirculation door Motor (V113) are installed.

3 Recirculated Air Door

Shown in "closed" position.

Air conditioners (heaters) whose back pressure/fresh air door is operated by the Air Flow door Motor (V71) and whose recirculation door is operated by the Recirculation door Motor (V113) are installed.

4 Fresh Air Blower (V2)

With Fresh Air Blower Control Module (J126).

5 Dust and Pollen Filter

Follow the replacement intervals.

There are different versions of the dust and pollen filter (with and without an activated charcoal insert). Refer to the Electronic Parts Catalog (ETKA). An Audi TT with A/C has a dust and pollen filter with an activated charcoal insert is installed. An Audi TT without A/C has a dust and pollen filter without the activated charcoal insert.

6 Evaporator

In vehicles without A/C system (with heater only), a foam core piece is installed for noise insulation instead of evaporator.

7 Lower Section Of Evaporator Housing (With Installed Components)

Air guide channel lower section, vehicles without A/C (with heating only).

8 Air Outlet To Air Distribution Housing

9 Air Distribution Housing