Operation CHARM: Car repair manuals for everyone.

Symptom Related Diagnostic Procedures

Diagnostic Chart:




Wiring Diagram:





CIRCUIT DESCRIPTION
The ignition switch supplies Ignition voltage to the Inflatable Restraint Sensing and Diagnostic Module (SDM) using the SIR Fuse. The ignition switch also supplies Ignition 1 voltage to the Instrument Panel Cluster (IP). The AIR BAG warning lamp is controlled by the SDM via Class 2 serial data.

When you turn ON the ignition, the SDM responds by performing tests on the SIR system and then commanding the AIR BAG warning lamp OFF after it has flashed seven times.

DIAGNOSTIC AIDS
If battery voltage is outside of the normal operating voltage range (9 volts-16 volts), the AIR BAG warning lamp will come ON solid with no DTCs set.