Air Conditioning (A/C) Refrigerant Pressure Sensor Replacement (Non-HP2)
Air Conditioning (A/C) Refrigerant Pressure Sensor Replacement (Non-HP2)
Special Tools
J 39400-A Halogen Leak Detector
Removal Procedure
1. Disconnect the electrical connector from the A/C refrigerant pressure sensor.
2. Remove the A/C refrigerant pressure sensor (1) from the condenser tube.
Installation Procedure
Caution: Refer to Fastener Caution (Fastener Caution).
1. Install the A/C refrigerant pressure sensor (1).
Tighten the switch to 6 Nm (53 lb in).
2. Connect the electrical connector to the A/C refrigerant pressure sensor.
3. Leak test the fittings of the components using the J 39400-A .
4. Lower the vehicle.