Canister Purge Solenoid: Service and Repair
Evaporative Emission Canister Purge Solenoid Valve Replacement
Removal Procedure
Important:
Clean all evaporative emission (EVAP) line connections and surrounding areas prior to disconnecting, in order to avoid possible EVAP system contamination.
1. Remove the air cleaner assembly. Refer to Air Cleaner Assembly Replacement Service and Repair.
2. Disconnect the EVAP line quick connect fitting from the EVAP canister purge solenoid. Refer to Plastic Collar Quick Connect Fitting Service Procedures.
3. Disconnect the engine wiring harness electrical connector (2) from the EVAP canister purge solenoid.
4. Disconnect the chassis EVAP line quick connect fitting from the EVAP canister purge solenoid.
5. Disengage the retainer securing the EVAP canister purge solenoid to the fuel rail.
6. Remove the EVAP canister purge solenoid.
Installation Procedure
1. Install the EVAP canister purge solenoid.
2. Install the EVAP canister purge solenoid to the fuel rail and engage the retainer.
3. Connect the engine wiring harness electrical connector (2) to the EVAP canister purge solenoid.
4. Connect the chassis EVAP line quick connect fitting to the EVAP canister purge solenoid. Refer to Plastic Collar Quick Connect Fitting Service Procedures.
5. Connect the EVAP line quick connect fitting to the EVAP canister purge solenoid.
6. Install the air cleaner assembly. Refer to Air Cleaner Assembly Replacement Service and Repair.