P0139
Tests 1 - 4:
Tests 5 - 10:
Test 11:
SYMPTOM
P0139 - 1/2 O2 SENSOR SLOW RESPONSE
TEST NOTE
This symptom is diagnosed using the test P0133 - 1/1 O2 SENSOR SLOW RESPONSE.
WHEN MONITORED
Start engine. Allow engine to idle. For 1st part of test, if limits are exceeded, test passes. If not, 2nd part of test runs. ambient/battery temperature > 44 °F, Baro > 22.13 " H20, Battery > 10.5 volts, MAP > 11.79 & < 18.15 " H20, RPM > 1350 & < 2200 and VSS > 50 and < 65.
SET CONDITION
The oxygen sensor signal voltage is switching from below 0.39 volts to above 0.58 volts and back fewer times than required.
POSSIBLE CAUSES
- Exhaust leak
- O2 sensor heater feed circuit open
- O2 sensor heater ground circuit open
- O2 sensor sensor ground circuit voltage drop
- O2 sensor signal circuit voltage drop
- Wiring harness intermittent problem
- O2 sensor