Generator - Removal
3.7L/4.7L
CAUTION: Disconnect the negative battery cable before removing the battery output wire from generator. Failure to do so can result in injury or damage to electrical system.
1. Disconnect the negative battery cable.
2. Remove the generator drive belt Serpentine Accessory Drive Belt - Removal.
3. Unsnap the plastic insulator cap (3) from the B+ output terminal.
4. Remove the B+ terminal mounting nut (2) at the rear of the generator. Disconnect the B+ terminal eyelet from generator from the output stud.
5. Disconnect the field wire electrical connector (4) at the rear of the generator by pushing on the connector tab.
6. Remove the one rear vertical generator mounting bolt (2).
7. Remove the two front horizontal generator mounting bolts (1).
8. Remove the generator from vehicle.