Test F: LFC 15/DTC B1887 - Air Bag Driver Circuit Shorted to Ground
PINPOINT TEST F: LFC 15/DTC B1887 - AIR BAG DRIVER CIRCUIT SHORTED TO GROUNDF1-F3:
F3-F5:
F6-F7:
Normal Operation
The restraints control module (RCM) checks for a driver air bag module circuit short to ground fault by monitoring the voltage of circuits 614 (GY/OG) and 615 (GY/WH) at pins 3 and 4. If the RCM detects a short to ground on either of these pins, it will store a diagnostic trouble code (DTC) B1887 in memory and flash a lamp fault code (LFC) 15 (or higher priority code if one exists) on the air bag indicator.
Possible Causes
A driver air bag module circuit short to ground can be caused by:
- wiring, terminals and connectors.
- a faulted clockspring.
- a faulted driver air bag module.
- a faulted RCM.