Operation CHARM: Car repair manuals for everyone.

Hazard Lamps Malfunction




Hazard Lamps Malfunction

Diagnostic Instructions

* Perform the Diagnostic System Check - Vehicle Diagnostic System Check - Vehicle prior to using this diagnostic procedure.

* Review Strategy Based Diagnosis Strategy Based Diagnosis for an overview of the diagnostic approach.

* Diagnostic Procedure Instructions Diagnostic Procedure Instructions provides an overview of each diagnostic category.

Diagnostic Fault Information






Circuit/System Description

The body control module (BCM) controls the hazard lamps based on inputs from the hazard switch. With the hazard switch closed, a ground path is provided on the hazard switch signal circuit, indicating a hazard lamp request. When this request is seen, the BCM will pulse the turn signal lamp control circuits, illuminating the turn signal lamps.

Reference Information

Schematic Reference

Exterior Lights Schematics Exterior Lights Schematics

Connector End View Reference

Component Connector End Views A/C Compressor Clutch

Description and Operation

Exterior Lighting Systems Description and Operation Exterior Lighting Systems

Electrical Information Reference

* Circuit Testing Circuit Testing

* Connector Repairs Connector Repairs

* Testing for Intermittent Conditions and Poor Connections Testing for Intermittent Conditions and Poor Connections

* Wiring Repairs Wiring Repairs

Scan Tool Reference

Control Module References Control Module References for scan tool information

Circuit/System Verification

1. Ignition ON, observe the scan tool Hazard Lamp Switch parameter while applying and releasing the hazard switch. The reading should change between Active and Inactive.

If the parameter does not change between the commanded states, refer to Circuit/System Testing.

2. Observe the right and left turn signal lamps while applying and releasing the hazard lamp switch. The right and left turn signal lamps should flash ON and OFF while the hazard lamp switch is ON and remain OFF when the hazard lamp switch is OFF.

If the turn signal lamps do not cycle between the selected states, refer to Turn Signal Lamps and/or Indicators Malfunction Turn Signal Lamps and/or Indicators Malfunction.

3. Command the Lamp Test ON and OFF with a scan tool. The left and right turn signal indicators should turn ON and OFF when changing between the commanded states.

If the left and right turn signal indicators illuminate during the test, replace the BCM.

If the left and right turn signal indicators do not illuminate during the test or remain illuminated at all times, replace the instrument panel cluster.

Circuit/System Testing

1. Ignition OFF, disconnect the harness connector at the hazard switch.

2. Test for less than 5.0 ohms between the ground circuit terminal B and ground.

If greater than the specified range, test the ground circuit for an open/high resistance.

3. Ignition ON, verify the scan tool Hazard Lamp Switch parameter is Inactive.

If not the specified value, test the signal circuit terminal C for a short to ground. If the circuit tests normal, replace the BCM.

4. Install a 3 A fused jumper wire between the signal circuit terminal C and the ground circuit terminal B. Verify the scan tool Hazard Lamp Switch parameter is Active.

If not the specified value, test the signal circuit for a short to voltage or and open/high resistance. If the circuit tests normal, replace the BCM.

5. If all circuits test normal, test or replace the hazard switch.

Repair Instructions

Perform the Diagnostic Repair Verification Verification Tests after completing the diagnostic procedure.

* Hazard Warning Switch Replacement Service and Repair

* Control Module References Control Module References for BCM or instrument cluster replacement, programming and setup