DTC B1-11
DTC B1-11: No Signal from the Roll Rate SensorSpecial Tools Required
- SRS inflator simulator 07SAZ-TB4011A
- SRS simulator lead H 07YAZ-S3AA100
1. Erase the DTC memory.
2. Turn the ignition switch ON (II), and check that the SRS indicator comes on for about 6 seconds and then goes off.
Does the SRS indicator stay on, and is DTC B1-11 indicated?
YES - Go to step 3.
NO - Intermittent failure, system is OK at this time. Go to Troubleshooting Intermittent Failures. Diagnostic Strategies If another DTC is indicated, go to the DTC Troubleshooting Index. DTC List - Supplemental Restraint System
3. Turn the ignition switch OFF. Disconnect the battery negative cable, and wait for 3 minutes.
4. Check the connections between the floor wire harness 2P connector and the roll rate sensor.
Is the connection OK?
YES - Go to step 5.
NO - Repair the poor connection and retest. If the DTC B1-11 is still present, go to step 5.
5. Disconnect the floor wire harness 2P connector (A) from the roll rate sensor.
6. Disconnect SRS unit connector C (28P) from the SRS unit.
7. Check resistance between the No. 13 and No. 14 terminals of SRS unit connector C (28P). There should be an open circuit or at least 1 MOhm.
Is the resistance as specified?
YES - Go to step 8.
NO - Short in the floor wire harness; replace the floor wire harness.
8. Check resistance between the No. 13 terminal of SRS unit connector C (28P)and body ground, and between the No. 14 terminal and body ground. There should be an open circuit or at least 1 MOhm.
Is the resistance as sped fled?
YES - Go to step 9.
NO - Short to ground in the floor wire harness; replace the floor wire harness.
9. Reconnect the battery negative cable.
10. Turn the ignition switch ON (II).
11. Check for voltage between the No. 13terminalof SRS unit connector C (28P) and body ground, and between the No. 14 terminal and body ground. There should be 1 V or less.
Is the voltage as specified?
YES - Go to step 12.
NO - Short to power in the floor wire harness; replace the floor wire harness.
12. Turn the ignition switch OFF.
13. Connect the SRS inflator simulator (jumper connector) and simulator lead H to the floor wire harness 2P connector (A).
14. Check resistance between the No. 13 and No. 14 terminals of SRS unit connector C (28P). There should be 0 - 1.0 Ohm, or less.
Is the resistance as specified?
YES - Faulty roll rate sensor or SRS unit; replace the roll rate sensor. If the problem is still present, replace the SRS unit.
NO - Open in the floor wire harness; replace the floor wire harness.