CONSULT-II Setting Procedure
CONSULT-II SETTING PROCEDURECAUTION: If CONSULT-II is used with no connection of CONSULT-II CONVERTER, malfunctions might be detected in self-diagnosis depending on control unit which carry out CAN communication.
^ For details, refer to the separate CONSULT-II Operations Manual.
1. Turn ignition switch OFF.
2. Connect CONSULT-II and CONSULT-II CONVERTER to data link connector, which is located in instrument lower panel on driver side.
3. Turn ignition switch ON. (Do not start engine.)
4. Touch START (NISSAN BASED VHCL).
5. Touch A/T.
If A/T is not indicated, go to GI-39, "CONSULT-II Data Link Connector (DLC) Circuit". Electrical Diagrams
6. Perform each diagnostic test mode according to each service procedure.